Point Sensor Pulse Counter
418 MHz Transmitter
Main Features
|
30-Bit unique ID with 24-bit Digital Counter and radio transmitter
Counts up to 60,000 pulses per minute
Switch for installation and service mode indication
Broad operating temperature range
Up to 600-foot range
Transmission rates from 10 to 17 seconds random
Up to 100 transmitters can coexist
Battery lasts from 6 to 10 years
Very small (1.3” X 2.1” X .6”) ABS Enclosure
Complies with part 15 of the FCC rules
Water resistant coating on PCB
CRC-16 checked Status, ID, and counter data
Internal Loop antenna
Low Cost
|
|

|
Description:
The Point Sensor Pulse Counter wireless transmitter is a battery operated digital counter with a microprocessor controlled 418 MHz. FCC certified radio transmitter. The Point Sensor Pulse Counter has an on board time of day clock that allows it to spend most of the time in a low power quiescent state. At predetermined time intervals the clock will wake up the onboard microprocessor. Unique serial number information is read from a Dallas Semiconductor 1-wire digital device and counter data is read from a 24-bit internal counter register. This information is combined with a CRC-16 error check and transmitted in a very short data packet that results in a transmitter on time of only 15 milliseconds. This architecture allows the Point Sensor Pulse Counter to consume very little energy and a battery life of 5 to 10 years results.
The Point Sensor Pulse Counter electronics are coated with a conformal material that provides a moisture barrier against condensation. Submersion in water is not recommended. A pushbutton switch in the ABS cover allows the user to activate the service mode. The service switch has three functions: 1)The Point Sensor Pulse Counter is shipped with the transmitter turned off, anytime the Point Sensor Pulse Counter is to be shipped the transmitter should be turned off or placed in a shielded container to prevent interference. Start the Point Sensor Pulse Counter by a momentarily push of the service switch (you will feel the button click) the Point Sensor Pulse Counter is started. 2)The service switch is used as an aid to installation, when the service switch is pushed a data transmission occurs immediately and a special mark is introduced in the ID field of the transmitted data packet to indicate which sensor is in service or installation. 3)The service switch is used to put the Point Sensor Pulse Counter in a quiescent mode (no transmissions and very low power consumption), this is the state the Point Sensor Pulse Counter is in when you receive it from the manufacturer. Push and hold the service switch for 5 seconds or more to enter this powered down state.
Technical Features:
| PARAMETER |
UNITS |
| Transmission rate |
10-17 seconds random |
| Shelf life with battery installed |
10 Years in quiescent mode |
| Dimensions (enclosure) |
1.5 W X 2.1 H X .6 D (inches) |
| Weight |
1.5 oz. |
| Operating Temperature |
-40° to 85° C |
| Input |
2.8 to 5.5 vdc pulses (Up to 60,000 ppm) |
| Humidity |
0% to 90% non-condensing |
| Battery life with transmissions |
6-10 years with tx period of 30-240 seconds |
| Battery |
3.6 volt Lithium |
| FCC Certified |
FCC ID: M5ZCNT |